Details Chevron Down

Jung Basiclogo control JP44439
  • Control for level-dependent switching on and time-dependent switching off of a direct starting
  • explosion-proof three-phase submersible pump
  • preferably MultiCut pump
  • Two independent dynamic pressure level sensors for 'On/Off' and automatic emergency switching with alarm message as standard
  • ATEX-compliant monitoring of motor temperature and running time
  • Dry-run protection with immersion switch and safety barrier
  • Adjustable pump run-on time ( 2000 -60s)
  • with coupled switch-on delay
  • ( 1930 -10s) after power failure
  • Indicator lights for pump operation
  • Motor overcurrent
  • Engine overtemperature
  • Engine running time exceeded
  • Flood
  • Water shortage
  • Rotating field wrong
  • Alarm system (network dependent): potential-free and acknowledgeable closer
  • e.g. for connecting a 230 V flashing or warning light
  • optionally cyclic potential-free contact for remote fault reporting electronic buzzer
  • optionally clocked and acknowledgeable Battery charging circuit for mains-independent operation of the alarm system using an optional battery

Reviews Chevron Down

Write Your Own Review
You're reviewing:Jung Basiclogo control JP44439 AD 46 EXM,TLS, 15 m, with dynamic pressure level sensor
** Average Wholesale Price