with inlet pressure gauge ( 1930 -25 bar) and outlet pressure gauge ( 1930 -25 bar)
with molded seal
Screws and assembly hex key
Can be retrofitted with a pressure reducer cartridge (factory no. 2315.01.934)
min. operating pressure: 2 bar
max. operating pressure: 16 bar
Max. operating temperature: 30 °C
Medium: Drinking water
Installation position: any
with angle funnel ( Zubehör ) also horizontal
Lower passband width: 90 µm
Upper passband width: 125 µm
ABP. No. P-IX 7564/I (DN 32)
Notice
Please note that gas and electric appliances require increased mains voltage for proper operation. These appliances are not equipped with a two-pin mains plug. The installation of non-pluggable appliances must be carried out by the respective network operator or a certified specialist company, which can also assist you in obtaining any necessary approval from the relevant network operator for the installation of the appliance.